85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 480 V AC 50/60 Hz conforming to UL 508
Performance level
N 50 kA 415 V AC
Trip unit name
MicroLogic 2.3
Trip unit technology
Electronic
Trip unit protection functions
LSoI
control type
Toggle
Circuit breaker mounting mode
Fixed
Complementary
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ics] rated service short-circuit breaking capacity
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 42 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Mechanical durability
15000 cycles
Electrical durability
8000 cycles at 440 V In/2 4000 cycles at 440 V In 6000 cycles at 690 V In/2 2000 cycles at 690 V In
Power dissipation per pole
39.69 W
mounting support
Backplate
Mounting position
Horizontal and vertical Flat on the back
Upside connection
Front
downside connection
Front
Connection pitch
45 mm
Protection type
L : for overload protection (long time) So : for short time short-circuit protection with fixed delay I : for instantaneous short-circuit protection
Trip unit rating
630 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable 9 settings
[Ir] long-time protection pick-up adjustment range
250...630 A
Long-time protection delay adjustment type tr
Fixed
[tr] long-time protection delay adjustment range
400 s at 1.5 x Ir 16 s at 6 x Ir 11 s at 7.2 x Ir
Neutral protection settings
0.5 x Ir (3D + N/2) 1 x Ir (4D) No protection (3D)
Thermal memory
20 minutes before and after tripping
Short-time protection pick-up adjustment type Isd
Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range
1.5...10 x Ir
Short-time protection delay adjustment type tsd
Fixed
Instantaneous protection pick-up adjustment type Ii
Fixed
[Ii] instantaneous protection pick-up adjustment range
6900 A
earth-leakage protection
Without
Zone selective interlocking ZSI
Without
Number of slots for electrical auxiliaries
6 slot(s)
Local signalling
Flashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
Width (W)
185 mm
Height (H)
255 mm
Depth (D)
110 mm
Net weight
8.13 kg
Environment
standards
EN/IEC 60947
product certifications
CCC EAC Marine
You may also like
Recently viewed
Produk Berkualitas
Produk yang kami jual selalu asli, baru dan bergaransi
Hemat Waktu
Hemat waktu anda, cukup hubungi kami, kebutuhan anda akan kami antarkan ke tempat anda.
Staff Berpengalaman
Staff yang responsif dengan pengalaman 25 tahun akan selalu membantu anda
Lokasi Mudah
Kami memiliki 4 toko offline di lokasi yang strategis untuk mendukung melayani anda lebih baik lagi yaitu : - GMP LTC Glodok Jakarta Pusat - GMP Lippo Cikarang - GMP Jababeka Cikarang - GMP Deltamas Kabupaten Bekasi
Halo!
Silahkan bertanya kepada kami. Kami siap membantu anda