- GDK: Pcs - HRC: Pcs - LIC: Pcs - PST: Pcs
Description
Range of Product | Altivar 12 |
---|---|
Product or Component Type | Variable speed drive |
Product Specific Application | Simple machine |
Mounting Mode | Cabinet mount |
Communication Port Protocol | Modbus |
Supply frequency | 50/60 Hz +/- 5 % |
[Us] rated supply voltage | 200...240 V - 15...10 % |
Nominal output current | 4.2 A |
Maximum Horse Power Rating | 1 hp |
Motor power kW | 0.75 kW |
Maximum Horse Power Rating | 1 hp |
EMC filter | Integrated |
IP degree of protection | IP20 |
Discrete input number | 4 |
---|---|
Discrete output number | 2 |
analogue input number | 1 |
analogue output number | 1 |
Relay output number | 1 |
Physical interface | 2-wire RS 485 |
Connector Type | 1 RJ45 |
Continuous output current | 4.2 A 4 kHz |
Method of access | Server Modbus serial |
Speed drive output frequency | 0.5…400 Hz |
Speed range | 1…20 |
Sampling duration | 20 ms +/- 1 ms logic input 10 ms analogue input |
Linearity error | +/- 0.3 % of maximum value analogue input |
Frequency resolution | Analog input converter A/D, 10 bits Display unit 0.1 Hz |
Time constant | 20 ms +/- 1 ms for reference change |
Transmission Rate | 9.6 kbit/s 19.2 kbit/s 38.4 kbit/s |
Transmission frame | RTU |
Number of addresses | 1…247 |
Data format | 8 bits, configurable odd, even or no parity |
Communication service | Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43) |
Type of polarization | No impedance |
4 quadrant operation possible | False |
Asynchronous motor control profile | Quadratic voltage/frequency ratio Voltage/frequency ratio (V/f) Sensorless flux vector control |
Maximum output frequency | 4 kHz |
Transient overtorque | 150…170 % of nominal motor torque depending on drive rating and type of motor |
Acceleration and deceleration ramps | Linear from 0 to 999.9 s U S |
Motor slip compensation | Preset in factory Adjustable |
Switching frequency | 2...16 kHz adjustable 4...16 kHz with derating factor |
Nominal switching frequency | 4 kHz |
Braking to standstill | By DC injection |
Brake chopper integrated | False |
Line current | 10.2 A 100 V heavy duty) 8.5 A 120 V heavy duty) |
Maximum Input Current per Phase | 8.5 A |
Maximum output voltage | 240 V |
Apparent power | 2.0 kVA 240 V heavy duty) |
Maximum transient current | 6.3 A 60 s heavy duty) 6.9 A 2 s heavy duty) |
Network Frequency | 50-60 Hz |
Relative symmetric network frequency tolerance | 5 % |
Prospective line Isc | 1 kA |
Base load current at high overload | 4.2 A |
Power dissipation in W | Natural 44.0 W |
With safety function Safely Limited Speed (SLS) | False |
With safety function Safe brake management (SBC/SBT) | False |
With safety function Safe Operating Stop (SOS) | False |
With safety function Safe Position (SP) | False |
With safety function Safe programmable logic | False |
With safety function Safe Speed Monitor (SSM) | False |
With safety function Safe Stop 1 (SS1) | False |
With sft fct Safe Stop 2 (SS2) | False |
With safety function Safe torque off (STO) | False |
With safety function Safely Limited Position (SLP) | False |
With safety function Safe Direction (SDI) | False |
Protection type | Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t |
tightening torque | 7.08 lbf.in (0.8 N.m) |
insulation | Electrical between power and control |
Quantity per Set | Set of 1 |
Width | 2.83 in (72 mm) |
Height | 5.63 in (143 mm) |
Depth | 5.17 in (131.2 mm) |
Net Weight | 1.76 lb(US) (0.8 kg) |
Operating altitude | > 3280.84...6561.68 ft (> 1000...2000 m) with current derating 1 % per 100 m <= 3280.84 ft (1000 m) without derating |
---|---|
Operating position | Vertical +/- 10 degree |
Product Certifications | NOM CSA C-tick UL GOST RCM KC |
Marking | CE |
standards | UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3 |
Assembly style | With heat sink |
Electromagnetic compatibility | Electrical fast transient/burst immunity test level 4 EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 EN/IEC 61000-4-3 Surge immunity test level 3 EN/IEC 61000-4-5 Voltage dips and interruptions immunity test EN/IEC 61000-4-11 |
Environmental class (during operation) | Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3 |
Maximum acceleration under shock impact (during operation) | 150 m/s² at 11 ms |
Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 13...200 Hz |
Maximum deflection under vibratory load (during operation) | 1.5 mm at 2...13 Hz |
Overvoltage category | Class III |
Regulation loop | Adjustable PID regulator |
Electromagnetic emission | Radiated emissions environment 1 category C2 EN/IEC 61800-3 2...16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2...12 kHz shielded motor cable <16.40 ft (5 m) Conducted emissions with integrated EMC filter environment 1 category C2 EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <32.81 ft (10 m) Conducted emissions with additional EMC filter environment 1 category C1 EN/IEC 61800-3 4...12 kHz shielded motor cable <65.62 ft (20 m) Conducted emissions with additional EMC filter environment 1 category C2 EN/IEC 61800-3 4...12 kHz shielded motor cable <164.04 ft (50 m) Conducted emissions with additional EMC filter environment 2 category C3 EN/IEC 61800-3 4...12 kHz shielded motor cable <164.04 ft (50 m) |
Vibration resistance | 1 gn 13…200 Hz)EN/IEC 60068-2-6 1.5 mm peak to peak 3…13 Hz) - drive unmounted on symmetrical DIN rail - EN/IEC 60068-2-6 |
Shock resistance | 15 gn 11 ms EN/IEC 60068-2-27 |
Relative humidity | 5…95 % without condensation IEC 60068-2-3 5…95 % without dripping water IEC 60068-2-3 |
Noise level | 0 dB |
Pollution degree | 2 |
Ambient air transport temperature | -13…158 °F (-25…70 °C) |
Ambient air temperature for operation | 14…104 °F (-10…40 °C) without derating 104…140 °F (40…60 °C) with current derating 2.2 % per °C |
Ambient Air Temperature for Storage | -13…158 °F (-25…70 °C) |
Category | 22042-ATV12 DRIVE AND ACCESSORIES |
---|---|
Discount Schedule | CP4B |
GTIN | 3606480071072 |
Returnability | Yes |
Country of origin | ID |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 4.61 in (11.700 cm) |
Package 1 Width | 7.48 in (19.000 cm) |
Package 1 Length | 7.68 in (19.500 cm) |
Package 1 Weight | 2.46 lb(US) (1.118 kg) |