MAIN |
Range of product |
Telemecanique Limit switches XC Standard |
Series name |
Standard format |
Product or component type |
Limit switch |
Device short name |
XCKM |
Body type |
Fixed |
Head type |
Plunger head |
Material |
Metal |
Body material |
Zamak |
Fixing mode |
By the body |
Movement of operating head |
Linear |
Type of operator |
Spring return plunger metal |
Type of approach |
Vertical approach, 1 direction |
Cable entry |
3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm |
Number of poles |
2 |
Contacts type and composition |
1 NC + 1 NO |
Contact operation |
Snap action |
COMPLEMENTARY |
Switch actuation |
On end |
Electrical connection |
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
Contacts insulation form |
Zb |
Number of steps |
1 |
Positive opening |
With |
Positive opening minimum force |
45 N |
Minimum force for tripping |
15 N |
Minimum actuation speed |
0.01 m/min |
Maximum actuation speed |
0.5 m/s |
Repeat accuracy |
0.05 mm on the tripping points with 1 million operating cycles |
Contact code designation |
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
[Ithe] conventional enclosed thermal current |
10 A AC |
[Ui] rated insulation voltage |
300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to CSA C22.2 No 14 |
Maximum resistance across terminals |
25 MOhm conforming to IEC 60255-7 category 3 |
[Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 |
Short-circuit protection |
10 A cartridge fuse, type gG |
Electrical durability |
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
Mechanical durability |
20000000 cycles |
Width |
64 mm |
Height |
64 mm |
Depth |
30 mm |