| MAIN |
| Range of product |
Telemecanique Limit switches XC Standard |
| Series name |
Standard format |
| Product or component type |
Limit switch |
| Device short name |
XCKM |
| Body type |
Fixed |
| Head type |
Plunger head |
| Material |
Metal |
| Body material |
Zamak |
| Fixing mode |
By the body |
| Movement of operating head |
Linear |
| Type of operator |
Spring return roller plunger metal |
| Type of approach |
Lateral approach, 2 directions |
| Cable entry |
3 entries tapped for M20 x 1.5 cable gland, cable outer diameter: 7…13 mm |
| Number of poles |
2 |
| Contacts type and composition |
1 NC + 1 NO |
| Contact operation |
Snap action |
| COMPLEMENTARY |
| Switch actuation |
By 30° cam |
| Electrical connection |
Screw-clamp terminals, clamping capacity: 1 x 0.34...2 x 1.5 mm² |
| Contacts insulation form |
Zb |
| Number of steps |
1 |
| Positive opening |
With |
| Positive opening minimum force |
36 N |
| Minimum force for tripping |
12 N |
| Minimum actuation speed |
0.01 m/min |
| Maximum actuation speed |
0.5 m/s |
| Contact code designation |
A300, AC-15 (Ue = 240 V), Ie = 3 A conforming to EN/IEC 60947-5-1 appendix A Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1 appendix A |
| [Ithe] conventional enclosed thermal current |
10 A AC |
| [Ui] rated insulation voltage |
300 V conforming to UL 508 500 V (pollution degree 3) conforming to IEC 60947-1 300 V conforming to CSA C22.2 No 14 |
| Maximum resistance across terminals |
25 MOhm conforming to IEC 60255-7 category 3 |
| [Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60664 6 kV conforming to IEC 60947-1 |
| Short-circuit protection |
10 A cartridge fuse, type gG |
| Electrical durability |
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 24 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 5000000 cycles, DC-13, inductive load type, 48 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C |
| Mechanical durability |
20000000 cycles |
| Width |
64 mm |
| Height |
64 mm |
| Depth |
30 mm |
| Net weight |
0.255 kg |