Description
Range | TeSys TeSys Deca |
---|---|
Product name | TeSys CAD |
Product or Component Type | Control relay |
Device short name | CAD |
contactor application | Control circuit |
utilisation category | AC-15 AC-14 DC-13 |
---|---|
Pole contact composition | 5 NO |
[Ue] rated operational voltage | <= 690 V AC 25...400 Hz |
Control circuit type | AC 50/60 Hz |
[Uc] control circuit voltage | 220 V AC 50/60 Hz |
[Uimp] rated impulse withstand voltage | 6 kV IEC 60947 |
[Ith] conventional free air thermal current | 10 A 140 °F (60 °C) |
Irms rated making capacity | 140 A AC IEC 60947-5-1 250 A DC IEC 60947-5-1 |
[Icw] rated short-time withstand current | 100 A - 1 s 120 A - 500 ms 140 A - 100 ms |
Associated fuse rating | 10 A gG IEC 60947-5-1 |
[Ui] rated insulation voltage | 600 V UL 600 V CSA 690 V IEC 60947-5-1 |
Mounting Support | Plate Rail |
Connections - terminals | Screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end |
Tightening torque | 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm 10.62 lbf.in (1.2 N.m) screw clamp terminals pozidriv No 2 |
Control circuit voltage limits | 0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz 0.8...1.1 Uc -40…140 °F (-40…60 °C) operational AC 50 Hz 0.85...1.1 Uc -40…140 °F (-40…60 °C) operational AC 60 Hz 1...1.1 Uc 140…158 °F (60…70 °C) operational AC 50/60 Hz |
Operating time | 12...22 ms coil energisation and NO closing 4...12 ms coil de-energisation and NO opening |
Mechanical durability | 30 Mcycles |
Maximum operating rate | 180 cyc/mn |
Inrush power in VA | 70 VA 50 Hz 68 °F (20 °C)) |
Hold-in power consumption in VA | 8 VA 50 Hz 68 °F (20 °C)) |
Minimum switching voltage | 17 V |
Minimum switching current | 5 mA |
Non-overlap time | 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact |
Insulation resistance | > 10 MOhm |
Mechanical robustness | Shocks control relay open10 Gn for 11 ms IEC 60068-2-27 Shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 Vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 Vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6 |
Height | 3.03 in (77 mm) |
Width | 1.77 in (45 mm) |
Depth | 3.31 in (84 mm) |
Net Weight | 1.28 lb(US) (0.58 kg) |
Standards | EN/IEC 60947-5-1 GB/T 14048.5 UL 60947-5-1 CSA C22.2 No 60947-5-1 JIS C8201-5-1 |
---|---|
Product Certifications | CB Scheme CCC UL CSA EAC CE UKCA |
IP degree of protection | IP2X front face VDE 0106 |
Protective treatment | TH IEC 60068 |
Ambient air temperature for operation | -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating |
Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) |
Operating altitude | 0...9842.52 ft (0...3000 m) |
Category | 22371-RELAYS, CONTROL |
---|---|
Discount Schedule | I12 |
GTIN | 3389110842463 |
Returnability | Yes |
Country of origin | ID |