Description
Range of product | Harmony |
---|---|
Product or component type | Programmable receiver |
Device short name | ZBRRA |
Product specific application | Interface to actuators |
function of module | Bi-stable Monostable Stop/start |
Reset time | 2 ms time delay |
Transmission frequency | 2405 MHz |
emission class | 5M00G7W |
Antenna type | Omnidirectional |
Nominal output current | 0.3 A at 48 V DC conforming to IEC 60947-5-1 3 A at 24 V DC conforming to UL 508 1.5 A at 240 V AC conforming to IEC 60947-5-1 3 A at 120 V AC conforming to IEC 60947-5-1 3 A at 240 V AC conforming to UL 508 3 A at 24 V DC conforming to CSA C22.2 No 14 3 A at 240 V AC conforming to CSA C22.2 No 14 |
---|---|
Output type | 2 relays |
Output contacts | 2 C/O |
Input output isolation | Galvanic isolation |
Time delay range | 0.5 s (tolerance: - 15...15 %) |
Switching capacity in VA | 1250 VA |
Maximum switching current | 5 mA AC/DC |
Maximum switching voltage | 250 V AC/DC |
[Us] rated supply voltage | 24...240 V AC/DC 50/60 Hz - 10...10 % |
Communication port protocol | Zigbee green power at 2.4 GHz conforming to IEEE 802.15.4 |
Maximum sensing distance | 100 m in free field 25 m transmitter in a plastic box type XAL D and receiver in a metal enclosure 40 m transmitter in box type XAL D, receiver in metal enclosure and use relay-antenna |
Response time | < 30 ms after transmitter clicks |
Utilisation category | AC-15 : B300 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 |
Maximum power consumption in W | 4 W AC/DC |
Breaking capacity | 15 W |
Breaking capacity | 750 VA |
control circuit frequency | 50...60 Hz +/- 10 % |
Short-circuit protection | 0.4 A fuse type fast blow |
Operating position | Any position without derating |
Electrical connection | 1 conductor cable 0.14…2.5 mm² - AWG 26...AWG 14 - solid - without cable end conforming to IEC 60947-1 2 conductors cable 0.14…1.5 mm² - AWG 26...AWG 16 - solid - without cable end conforming to IEC 60947-1 1 conductor cable 0.14…4 mm² - AWG 26...AWG 12 - flexible - with cable end conforming to IEC 60947-1 2 conductors cable 0.14…1.5 mm² - AWG 26...AWG 16 - flexible - with cable end conforming to IEC 60947-1 |
Tightening torque | 0.5…1 N.m conforming to IEC 60947-1 |
Housing material | Self-extinguishing plastic |
Status LED | 1 LED green for power ON 2 LEDs green for relay ON 2 LEDs green for function mode 1 LED green and yellow for reception signal |
Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 Mounting plate |
Rated short-duration power frequency withstand voltage | 1.5 kV 50 Hz conforming to IEC 60947-5-1 |
[Uimp] rated impulse withstand voltage | 4 kV |
Surge withstand | 1 kV differential mode conforming to IEC 61000-4-5 2 kV common mode conforming to IEC 61000-4-5 |
Max power consumption in W | 1 mW |
Number of channels | 1 |
Modulation Technique | O-QPSK |
Bandwidth | 5 MHz |
Antenna gain | 0 dBi |
Width | 36 mm |
height | 108 mm |
Depth | 75 mm |
Net weight | 0.13 kg |
standards | CSA C22.2 No 14 UL 508 IEC 60947-5-1 IEC 60947-1 |
---|---|
Radio agreement | RSS SRRC ANATEL ARIB T66 FCC ICASA |
product certifications | C-Tick CCC CSA UL GOST |
Marking | CE |
Ambient air temperature for storage | -40…70 °C |
Relative humidity | 90 % at -20…55 °C, without condensation conforming to ETSI EN 300 440-1 |
Vibration resistance | +/- 7.5 mm (f= 5…14 Hz) conforming to IEC 60068-2-6 2 gn (f= 8…150 Hz) conforming to IEC 60068-2-6 |
Shock resistance | 10 gn (duration = 16 ms) for 6000 shocks conforming to IEC 60068-2-27 |
IP degree of protection | IP20 (casing) conforming to IEC 60529 IP20 (terminals) |
Pollution degree | 2 conforming to IEC 60664-1 |
Overvoltage category | II conforming to IEC 60664-1 |
Insulation resistance | > 500 MOhm at 500 V DC conforming to NF C 20-030 |
[Ui] rated insulation voltage | 250 V conforming to IEC 60664-1 |
Electromagnetic compatibility | Immunity for industrial environments conforming to IEC 61000-6-2 Conducted and radiated emissions class B conforming to CISPR 22 Electrostatic discharge immunity test - test level: 8 kV (in free air (in insulating parts)) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (on contact (on metal parts)) conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80...2000 MHz) conforming to IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 3 V/m (80...2700 MHz, distance = 20 m) conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (power supply wires) conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (differential mode) conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test - test level: 2 kV (common mode) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V conforming to IEC 61000-4-6 Immunity to microbreaks and voltage drops - test level: 10 ms conforming to IEC 61000-4-11 Radiated emission conforming to ETSI EN 300 440-1 Conducted emission conforming to EN 300-489-1 Conducted emission conforming to ETSI EN 300 489-3 Radiated emission conforming to ETSI EN 300 440-2 |
Electrical durability | 100000 cycles |
Mechanical durability | 1000000 cycles |