| Control station type | 
Double insulated | 
| Enclosure material | 
Polypropylene | 
| Electrical circuit type | 
Control circuit | 
| Enclosure type | 
Complete ready for use | 
| Control station application | 
Control of 2-speed hoist motor | 
| Control station composition | 
2 push-buttons + 1 emergency stop | 
| Control button type | 
Stop push-button Ø 30 mm 1 NC latching First push-button 1 NC + 2 NO raise, slow-fast Second push-button 1 NC + 2 NO lower, slow-fast | 
| Product compatibility | 
ZB2BE102 for emergency stop XENG1191 for each direction | 
| Mechanical interlocking | 
With mechanical interlocking | 
| Control station colour | 
Yellow | 
| Connections - terminals | 
Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end | 
| standards | 
UL 508 CSA C22.2 No 14 EN/IEC 60947-5-1 EN/IEC 60204-32 | 
| product certifications | 
CCC GOST | 
| Protective treatment | 
TH | 
| Ambient air temperature for operation | 
-25…70 °C | 
| Ambient air temperature for storage | 
-40…70 °C | 
| Vibration resistance | 
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6 | 
| Shock resistance | 
100 gn conforming to IEC 60068-2-27 | 
| Overvoltage category | 
Class II conforming to IEC 61140 | 
| IP degree of protection | 
IP65 conforming to IEC 60529 | 
| IK degree of protection | 
IK08 conforming to EN 50102 | 
| Mechanical durability | 
1000000 cycles | 
| Cable entry | 
Rubber sleeve with stepped entry 8…26 mm | 
| Contact code designation | 
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A | 
| [Ithe] conventional enclosed thermal current | 
10 A | 
| [Ui] rated insulation voltage | 
600 V (pollution degree 3) | 
| [Uimp] rated impulse withstand voltage | 
6 kV conforming to IEC 60947-1 | 
| contact operation | 
Slow-break Staggered | 
| Maximum resistance across terminals | 
25 MOhm | 
| Operating force | 
18 N push-button 8 N emergency stop | 
| Short-circuit protection | 
10 A fuse protection by cartridge fuse type gG | 
| Rated operational power in W | 
40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C | 
| Terminals description ISO n°1 | 
(21-22)NC (13-14)NO (33-34)NO_CL | 
| Terminals description ISO n°2 | 
(11-12)NC | 
| Terminal identifier | 
(13-14)NO (11-12)NC | 
| Net weight | 
0.57 kg |