range |
PowerLogic
|
|
---|---|---|
product name |
PowerLogic PM5350
|
|
device short name |
PM5350
|
|
product or component type |
Power meter
|
power quality analysis |
total demand distortion
total harmonic distortion |
|
---|---|---|
device application |
Power monitoring
|
|
type of measurement |
Current
Voltage Frequency Power factor Energy Phase angle Apparent power Active power Reactive power |
|
supply voltage |
85...265 V AC 45...65 Hz
100...300 V DC |
|
network frequency |
50 Hz
60 Hz |
|
[In] rated current |
5 A
1 A |
|
type of network |
1P + N
3P + N 3P |
|
maximum power consumption in VA |
9.6 VA
|
|
ride-through time |
80 ms 120 V AC typical
100 ms 230 V AC typical 100 ms 415 V AC typical |
|
display type |
Backlit LCD
|
|
display resolution |
6 lines
|
|
sampling rate |
32 samples/cycle
|
|
measurement current |
0���1 A
0���5 A |
|
analogue input type |
Current 0.05...9 A (impedance <= 0.3 Ohm)
|
|
measurement voltage |
20���690 V AC phase to phase
20���400 V AC phase to neutral |
|
frequency measurement range |
45���70 Hz
|
|
number of inputs |
4 digital
|
|
measurement accuracy |
Current 0.3 %
Voltage 0.3 % Frequency 0.05 % Power factor +/- 05 |
|
accuracy class |
Class 0.5S active energy conforming to IEC 62053-22
Class 0.5 active energy conforming to IEC 61557-12 Class 3 reactive energy conforming to IEC 62053-23 Class 2 reactive energy conforming to IEC 61557-12 Class 0.5 power conforming to IEC 61557-12 |
|
number of outputs |
2 relay
|
|
information displayed |
Tariff (4)
|
|
communication port protocol |
JBUS
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds |
|
communication port support |
Terminal block: RS485
|
|
data recording |
Min/max of instantaneous values
Alarms |
|
connections - terminals |
Voltage circuit: screw terminal block4
Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 Relay output: screw terminal block4 Ethernet network: RJ45 connector |
|
mounting mode |
Flush-mounted
|
|
type of installation |
Indoor installation
|
|
standards |
IEC 61010-1
|
|
product certifications |
CE
CULus |
|
width |
96 mm
|
|
depth |
44 mm
|
|
height |
96 mm
|
|
net weight |
0.25 kg
|
electromagnetic compatibility |
Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
Electrostatic discharge conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 ��s shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Immunity to impulse waves conforming to IEC 61000-4-12 Conducted and radiated emissions class A conforming to EN 55011 Limits for harmonic current emissions conforming to IEC 61000-3-2 |
|
---|---|---|
overvoltage category |
III
|
|
IP degree of protection |
IP30 back: conforming to IEC 60529
IP51 front face: conforming to IEC 60529 |
|
relative humidity |
0���95 % at 50 ��C
|
|
pollution degree |
2
|
|
ambient air temperature for operation |
-40���85 ��C
|
|
ambient air temperature for storage |
-25���70 ��C
|
|
operating altitude |
0...3000 m
|