Current Voltage Frequency Power factor Energy Phase angle Apparent power Active power Reactive power
supply voltage
85...265 V AC 45...65 Hz 100...300 V DC
network frequency
50 Hz 60 Hz
[In] rated current
5 A 1 A
type of network
1P + N 3P + N 3P
maximum power consumption in VA
9.6 VA
ride-through time
80 ms 120 V AC typical 100 ms 230 V AC typical 100 ms 415 V AC typical
display type
Backlit LCD
display resolution
6 lines
sampling rate
32 samples/cycle
measurement current
0���1 A 0���5 A
analogue input type
Current 0.05...9 A (impedance <= 0.3 Ohm)
measurement voltage
20���690 V AC phase to phase 20���400 V AC phase to neutral
frequency measurement range
45���70 Hz
number of inputs
4 digital
measurement accuracy
Current 0.3 % Voltage 0.3 % Frequency 0.05 % Power factor +/- 05
accuracy class
Class 0.5S active energy conforming to IEC 62053-22 Class 0.5 active energy conforming to IEC 61557-12 Class 3 reactive energy conforming to IEC 62053-23 Class 2 reactive energy conforming to IEC 61557-12 Class 0.5 power conforming to IEC 61557-12
number of outputs
2 relay
information displayed
Tariff (4)
communication port protocol
JBUS Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds
communication port support
Terminal block: RS485
data recording
Min/max of instantaneous values Alarms
connections - terminals
Voltage circuit: screw terminal block4 Control circuit: screw terminal block2 Current transformer: screw terminal block6 Input/output circuit: screw terminal block6 Relay output: screw terminal block4 Ethernet network: RJ45 connector
mounting mode
Flush-mounted
type of installation
Indoor installation
standards
IEC 61010-1
product certifications
CE CULus
width
96 mm
depth
44 mm
height
96 mm
net weight
0.25 kg
Environment
electromagnetic compatibility
Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3 Electrostatic discharge conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 ��s shock waves immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Immunity to impulse waves conforming to IEC 61000-4-12 Conducted and radiated emissions class A conforming to EN 55011 Limits for harmonic current emissions conforming to IEC 61000-3-2
overvoltage category
III
IP degree of protection
IP30 back: conforming to IEC 60529 IP51 front face: conforming to IEC 60529
relative humidity
0���95 % at 50 ��C
pollution degree
2
ambient air temperature for operation
-40���85 ��C
ambient air temperature for storage
-25���70 ��C
operating altitude
0...3000 m
You may also like
Recently viewed
Produk Berkualitas
Produk yang kami jual selalu asli, baru dan bergaransi
Hemat Waktu
Hemat waktu anda, cukup hubungi kami, kebutuhan anda akan kami antarkan ke tempat anda.
Staff Berpengalaman
Staff yang responsif dengan pengalaman 25 tahun akan selalu membantu anda
Lokasi Mudah
Kami memiliki 4 toko offline di lokasi yang strategis untuk mendukung melayani anda lebih baik lagi yaitu : - GMP LTC Glodok Jakarta Pusat - GMP Lippo Cikarang - GMP Jababeka Cikarang - GMP Deltamas Kabupaten Bekasi
Halo!
Silahkan bertanya kepada kami. Kami siap membantu anda