{"product_id":"relay-schneider-rpm22p7-8-pin-flat-2-c-o-15a-230vac","title":"Relay Schneider RPM22P7 (8 Pin Flat) 2 C\/O 15A 230VAC","description":"\u003ctable class=\"specifications-table\"\u003e\n\u003ccaption class=\"specifications-table__caption\"\u003eMain\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eRange of product\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eHarmony Electromechanical Relays\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eSeries name\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003ePower\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eProduct or component type\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003ePlug-in relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eDevice short name\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text\"\u003eRPM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eContacts type and composition\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e2 C\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[Uc] control circuit voltage\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e230 V AC 50\/60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[Ithe] conventional enclosed thermal current\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e15 A at -40…55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eStatus LED\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eWith\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003econtrol type\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eLockable test button\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eUtilisation coefficient\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e20 %\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"specifications-table\"\u003e\n\u003ccaption class=\"specifications-table__caption\"\u003eComplementary\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eShape of pin\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eFlat\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[Ui] rated insulation voltage\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e250 V conforming to IEC\u003cbr\u003e300 V conforming to CSA\u003cbr\u003e300 V conforming to UL\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[Uimp] rated impulse withstand voltage\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e4 kV during 1.2\/50 µs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eContacts material\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eAgNi\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003e[Ie] rated operational current\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e15 A at 277 V (AC) conforming to UL\u003cbr\u003e15 A at 28 V (DC) conforming to UL\u003cbr\u003e15 A at 250 V (AC) NO conforming to IEC\u003cbr\u003e15 A at 28 V (DC) NO conforming to IEC\u003cbr\u003e7.5 A at 250 V (AC) NC conforming to IEC\u003cbr\u003e7.5 A at 28 V (DC) NC conforming to IEC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eMaximum switching voltage\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e250 V conforming to IEC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eResistive load current\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e15 A at 250 V AC\u003cbr\u003e15 A at 28 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eMaximum switching capacity\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e3750 VA\u003cbr\u003e420 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eMinimum switching capacity\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e170 mW at 10 mA, 17 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eOperating rate\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e\u0026lt;= 1200 cycles\/hour under load\u003cbr\u003e\u0026lt;= 18000 cycles\/hour no-load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eMechanical durability\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e10000000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eElectrical durability\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e100000 cycles for resistive load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eAverage coil consumption in VA\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e1.1 at 60 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eDrop-out voltage threshold\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e\u0026gt;= 0.15 Uc AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eOperate time\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e20 ms at nominal voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eRelease time\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e20 ms at nominal voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eAverage coil resistance\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e16270 Ohm at 20 °C +\/- 15 %\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eRated operational voltage limits\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e184...253 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eProtection category\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eRT I\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eTest levels\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eLevel A group mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eOperating position\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eAny position\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003ePollution degree\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eSafety reliability data\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eB10d = 100000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eNet weight\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e0.036 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eDevice presentation\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eComplete product\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"specifications-table\"\u003e\n\u003ccaption class=\"specifications-table__caption\"\u003eEnvironment\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eDielectric strength\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e1500 V AC between contacts with micro disconnection\u003cbr\u003e2000 V AC between coil and contact with reinforced\u003cbr\u003e2000 V AC between poles with basic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003estandards\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eCSA C22.2 No 14\u003cbr\u003eUL 508\u003cbr\u003eIEC 61810-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eproduct certifications\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eCSA\u003cbr\u003eUL\u003cbr\u003eEAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eAmbient air temperature for storage\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e-40…85 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eAmbient air temperature for operation\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e-40…55 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eVibration resistance\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e3 gn, amplitude = +\/- 1 mm (f = 10…150 Hz)5 cycles in operation\u003cbr\u003e5 gn, amplitude = +\/- 1 mm (f = 10…150 Hz)5 cycles not operating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eDegree of protection (Housing only)\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003eIP40 conforming to IEC 60529\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"specifications-table__row\"\u003e\n\u003cth class=\"specifications-table__row-heading\"\u003eShock resistance\u003c\/th\u003e\n\u003ctd class=\"specifications-table__cell\"\u003e\u003cspan class=\"specifications-table__text specifications-table__text--first-letter-uppercase\"\u003e15 gn for in operation\u003cbr\u003e30 gn for not operating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"SCHNEIDER","offers":[{"title":"Default Title","offer_id":39810899574859,"sku":"0012024","price":112000.0,"currency_code":"IDR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0272\/6311\/products\/files_9587eeac-67ef-4e84-bd07-b937fc08a35d.jpg?v=1756111159","url":"https:\/\/www.gmp-electric.com\/products\/relay-schneider-rpm22p7-8-pin-flat-2-c-o-15a-230vac","provider":"GMP Elektrik","version":"1.0","type":"link"}