- GDK: Pcs - HRC: Pcs - LIC: Pcs - PST: Pcs
Description
Current:0.5A~400A
Voltage:12V~680V
General Install Size
Vacuum Weld Techinics
Led indicator showing “ON” or “OFF”
Protect Panel
IEC standard
Input & output type could chose DC/AC AC/AC DC/DC
Overview
Solid State Relay(CSR) is industrial control appliances which use power semiconductor devices for main control part,compare with traditional magnetic contact industrial controllers, it is more high-powered, intelligent, digital, systematic and green development.
according switch mode CSR have zero-cross and random type. When the input control signal, random type conduction immediately, zero cross type need load voltage turn to zero region just can conduction. Revocation of the control signal,all can cut off when less than maintenance current. zero cross type may cause the maximum half-cycle delay, but reduces the impact of the load and radiofrequency interference, is the ideal switching devices.Random type fast response,suitable for dimmer,thermostats resistive loads and some inductive load applications.
When the CSR turn off, if in the phase current and voltage have different, will have a large rise rate (dv/dt) on the triac, such as dv/dt higher than Triac standatrd (300V/us), will result in delay shutdown even failure. use anti-parallel thyristor's CSR(powerful type) will been greatly improved at dv/dt(dv / dt is 500V/us). Therefore, in the field of capacitive load or inductive load, suggest the use powerful type CSR. CNTD's CSR are all powerful type.
Solid-state voltage regulator consists of thyristor switching circuit, resistance-capacitance phase shifting circuit,lag circuit and over-voltage absorption circuit.The use of only one external potentiometer can be used to achieve AC power regulation.In many occasions can replace the heavy contact voltage lighting power supply,voltage,temperature,brightness, speed and other analog adjustment.
AC DC switch & Temp control Automate Control
CNC machinery Packaging machinery
Textile machinery Glass machinery
Plastic machinery
Specification |
input parameter |
output parameter |
Safe Load |
|||||||||
Control Voltage |
Control Current |
Start Current |
Close Voltage |
Operating Current |
Operating Voltage |
Insulate voltage |
Protection |
Resistive Load |
Inductive Load |
|||
Over Voltage |
Over Current |
|||||||||||
CSR |
DC/ AC |
4-32 |
<20mA |
≥5mA |
≤1.5V |
10-100A |
24-480 |
≥2500 |
RC MOV |
Fast Fuse |
60% |
40% |
AC/AC |
80-250 |
<30mA |
≥5mA |
≤10V |
10-100A |
24-480 |
||||||
Industry class |
4-32 |
<20mA |
≥5mA |
≤1.5V |
100-800A |
24-480 |
||||||
DC/DC |
3-32 |
<25mA |
≥5mA |
≤1.5V |
10-40A |
12-250 |
Diode |
|||||
CTR |
4-32 |
<30mA |
≥9ma |
≤2.5V |
10-120A |
24-480 |
RC MOV |
Fast Fuse |
||||
Solid StateVoltage Regulator |
Potentiometer 500KΩ/1/4W |
10-40A |
10-250V AC |
RC MOV |
Fast Fuse |
RC: Built-in resistance capacity absorption circuit. MOV: External shunt metal oxide varistor.
Model |
CSR-DA |
CSR-AA |
CSR-VA |
CSR-DD |
CTR-DA |
|||
CSRE-DA |
CSRE-AA |
CSRE-VA |
CSRE-DD |
CTRE-DA |
||||
Operation Current |
10A,25A,40A |
60A,80A,100A |
10A,25A,40A |
60A,80A,100A |
10A,25A,40A |
10A,25A,40A |
10A,25A,40A |
60A,80A, |
Operation Voltage |
24-480V AC |
24-480V AC |
10-250V AC |
12-250V DC |
24-480V AC |
|||
Control Voltage |
4-32V DC |
80-250V AC |
500KΩ/1/4W |
3-32V DC |
4-32V DC |
|||
Control Current |
DC 3-25mA |
AC≤12mA |
/ |
DC 3-25mA |
DC 3-25mA |
|||
V TM |
≤1.5V |
≤1.5V |
≤1.5V |
≤1.5V |
≤1.5V |
≤2.3V |
≤1.5V |
≤1.5V |
I RRM |
≤10mA |
≤20mA |
≤10mA |
≤20mA |
≤5mA |
≤5mA |
≤15mA |
≤15mA |
T Q |
≤10mS |
≤10mS |
≤10mS |
≤10mS |
≤10mS |
|||
V iso |
2500V AC |
2500V AC |
2500V AC |
2500V AC |
2500V AC |
|||
R iso |
1000mΩ 500V DC |
1000mΩ 500V DC |
1000mΩ 500V DC |
1000mΩ 500V DC |
1000mΩ 500V DC |
|||
Tj |
-30~+80℃ |
-30~+80℃ |
-30~+80℃ |
-30~+80℃ |
-30~+80℃ |
|||
Weight |
90g |
140g |
90g |
140g |
90g |
90g |
350g |
450g |